Full Photovoltaic system for a new car park installation in Gateshead, Tyne and Wear .
Gateshead Car Park consists of a bespoke south facing 10 degree mounting system located on a steel frame canopy at roof level of a multi-story car park.
As there is no roof surface a bespoke PV mounting kit was designed to allow for the 222 solar panels to be mounted to the exposed steel purlins in a south facing orientation.
The system was installed on a 10 degree pitch and adequate spacing between rows to optimise sunlight throughout the day. 1x Ginlong (Solis) 100k-5G-PRO inverter was installed within the roof level plant room, the inverter was mounted on a custom built Unistrut frame.
Containment was installed along the steel runs of canopy to allow for DC cabling to be ran from the array strings to the inverter location. A Data logger was connected onto the inverter so that data can be viewed remotely.